Abstract

Current software applications for densitometric analysis, such as ImageJ, QuantityOne (BioRad) and the Intelligent or Advanced Quantifier (Bio Image) do not allow to take the non-linearity of autoradiographic films into account during calibration. As a consequence, quantification of autoradiographs is often regarded as problematic, and phosphorimaging is the preferred alternative. However, the non-linear behaviour of autoradiographs can be described mathematically, so it can be accounted for. Therefore, the ‘Densitometric Image Analysis Software’ has been developed, which allows to quantify electrophoretic bands in autoradiographs, as well as in gels and phosphorimages, while providing optimized band selection support to the user. Moreover, the program can determine protein-DNA binding constants from Electrophoretic Mobility Shift Assays (EMSAs). For this purpose, the software calculates a chosen stepwise equilibrium constant for each migration lane within the EMSA, and estimates the errors due to non-uniformity of the background noise, smear caused by complex dissociation or denaturation of double-stranded DNA, and technical errors such as pipetting inaccuracies. Thereby, the program helps the user to optimize experimental parameters and to choose the best lanes for estimating an average equilibrium constant. This process can reduce the inaccuracy of equilibrium constants from the usual factor of 2 to about 20%, which is particularly useful when determining position weight matrices and cooperative binding constants to predict genomic binding sites. The MATLAB source code, platform-dependent software and installation instructions are available via the website http://micr.vub.ac.be.

Highlights

  • To calibrate an autoradiograph, a calibrated step tablet should be scanned, preferrably together with the autoradiographic film to be analyzed, as the sensitivity of the scanner may change over time

  • Current software applications for densitometric analysis, such as ImageJ, QuantityOne (BioRad) and the Intelligent or Advanced Quantifier (Bio Image) do not offer the possibility of a second mapping and/ or a fit to the curve described by equation 1, and display the same non-linearity as the film

  • From stepwise equilibrium constants to a cooperative binding constant Here, we demonstrate how cooperative binding constants, i.e., binding constants corresponding to protein-protein interactions, can be determined in the case of homotypic cooperative protein binding at two non-overlapping sites

Read more

Summary

Introduction

A calibrated step tablet should be scanned, preferrably together with the autoradiographic film to be analyzed, as the sensitivity of the scanner may change over time. This section describes the entire program, how cooperative binding constants and their standard deviations can be determined, and a method to simulate smear caused by the dissociation of protein-DNA complexes.

Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.