Abstract

In this paper, flatwise tensile test (FWT) and modified double cantilever beam (DCB) experiment were conducted to investigated the debond fracture of sandwich plate with corrugated core. In the experiment, the crack always stays at the face/core interfacial. Tensile bond strength of face core can be given from the flatwise tensile test and we can get the mode I fracture toughness GIC from DCB tests. It is found that the trends of curves change greatly at the beginning, with the propagation of crack, load against open displacement curves change smoothly. In order to simulate the face/core failure of sandwich plate with corrugated core, the cohesive element model is used. Tensile strength and strain energy release rate measured by the experiments presented in this paper are used in as parameters for simulation of the debond fracture. By comparing with the experiment results, the model can express the face/core failure of sandwich plate with corrugated core validly.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.