Accurate and reliable beam position measurements are required to commission and operate the DARHT II Accelerator. The beam position monitor (BPM) system developed for use on the DARHT accelerator consists of 31 electro-magnetic detector assemblies, a computer network based data acquisition system, and analysis software. During each each BPM uses arrays of b-dot detectors to intercept the electron beam's changing magnetic field. The detector outputs are individually recorded. Post shot analysis of the data provides the beam current and position information. This paper will provide an overview of the system and give details regarding its performance.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.