Abstract

This study determined the effect of different light exposure times on the polymerization of three composite resins used as cements (Heliosit, Visio-Fil, and Dual) through various thicknesses and shades of two preprocessed composite resins (Isosit and Visio-Gem). The Knoop hardness of the surface of the luting resin was measured after polymerization and selected samples were remeasured at 24 hours to evaluate continued cure. Results indicated that polymerization of light-activated composite resin luting agents cannot predictably be accomplished through a restoration exceeding 2 mm in thickness using a light exposure of 90 seconds or less. The combined chemical and light-activated cure of Dual cement recorded the highest percentage of acceptable hardness values.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.