Abstract

In this paper, the cause and its serious hazard of the inter-turn short circuit fault on turbine generator rotor windings are analyzed. Furthermore the electromagnetic characteristics and mechanical characteristics as well as the correlative variety of the electrical parameters induced after inter-turn short circuit fault on turbine generator rotor windings are analyzed. Based on the fault characteristics that the excitation current increased while the reactive power output decreased relatively when the inter-turn short circuit happens, a fault characteristic mathematical model of inter-turn short circuit is founded considering the saturated situation of steam generators.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.