Abstract
Fatigue crack growth rate (FCGR) tests with different load ratios and dwell-fatigue crack growth rate (DFCGR) tests with different dwell times were conducted at 750°C for Incoloy 800H. As the load ratio increases from 0.1 to 0.5, the crack growth rate increased and the transition ΔK value from region I to region II (Paris regime) shifted leftward. In DFCGR tests with dwell time of 10 and 30 seconds, the Paris regime started at relatively lower ΔK level and the crack grew much faster than in FCGR tests. However, the crack growth rates between the 10 sec and 30 sec dwell times were relatively similar. The higher crack growth rates in the DFCGR tests compared to FCGR tests was associated with the reduction of the M23C6 precipitates in the vicinity of the advancing crack by the Cr depletion, suggesting the crack propagation in DFCGR conditions was environmentally assisted. The crack growth rate was controlled by trans-granular mode regardless of the dwell time because the dwell time was not enough to cause creep damage.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.