Abstract

The CPLEAR experiment will measure CP violation parameters in the neutral kaon system, using a low energy antiproton beam from the Low Energy Antiproton Ring (LEAR) at CERN. One of its subdetectors, the Particle Identification Detector (PID), makes a fast separation of pions and kaons, which is essential for the experiment. This article describes the design of the PID and its performance during beam tests and during initial runs at LEAR. A pion rejection efficiency of 99.7% for the first level trigger (after 60 ns) is found in the relevant momentum region.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call