Abstract
Instability is one of the causes of failure in total knee arthroplasty (TKA). The aim of this study was to analyze the correlation between objective ligament laxity and the clinical outcome of mechanically aligned TKA. Fifty-one knees in 47 patients were evaluated at a minimum follow-up of 6 months. The correlation between the angular displacement and functional scores (Knee Society Score and Knee Injury and Osteoarthritis Score) was analyzed. A negative correlation (p-value < 0.05) was observed between medial laxity ≥5° at 0, 30, 60, and 90° of flexion and the outcome measures. Lateral laxity did not correlate with the clinical outcome. At 30° of knee flexion, a total varus and valgus laxity ≥10° was related to poorer outcomes. The same amount of angular displacement did not influence the outcome in the other flexion angles. There was no difference in single-radius vs multi-radius implants in terms of medial and lateral laxity and clinical outcome. A valgus displacement ≥5° measured at 0, 30, 60, and 90 degrees of flexion correlated with an inferior clinical outcome. In contrast, the same amount of displacement measured on the lateral compartment did not influence the clinical outcome after TKA.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.