Abstract

ObjectiveThe purpose of the present study was to explore the correlation between the contrast-enhanced ultrasound (CEUS) and acoustic radiation force impulse (ARFI) characteristics of breast cancers and the expression of human epidermal growth factor receptor 2 (HER-2).MethodsHER-2 expression levels in the tumor masses of 167 clearly diagnosed cases of breast cancer were measured and analyzed. The enhancement features and time intensity curve (TIC) of CEUS and virtual touch tissue imaging (VTI) and virtual touch tissue quantification (VTQ) technology of ARFI were employed to analyze the relationship between HER-2 expression and the CEUS and ARFI characteristics of breast cancer.Results(1) Statistically significant differences in the distribution of the contrast agent, perforator blood flow, the overranging phenomenon and perfusion defects between the study groups with different HER-2 expression levels (P < 0.05) were observed on CEUS. In addition, statistically significant differences in the TIC peak time (PT), slope of the ascending branch (K) and area under the curve (AUC) were found in the groups expressing different levels of HER-2 (P < 0.05). In contrast, the degree of contrast agent enhancement and TIC peak intensity (PI) were found to be independent of the expression status of HER-2, as they were not statistically significant (P > 0.05). (2) Statistically significant differences in the VTQ results between the groups with different HER-2 expression levels were found (P < 0.05). However, no statistically significant differences in VTI image characteristics were detected between the groups expressing different levels of HER-2 (P > 0.05).ConclusionA correlation was found between the CEUS and ARFI characteristics of breast cancer and HER-2 expression levels. This correlation was principally reflected in perfusion defects, perforator blood flow, PI, PT, K and VTQ.

Highlights

  • Breast cancer is a common malignancy in females

  • The enhancement features and time intensity curve (TIC) of contrast-enhanced ultrasound (CEUS) and virtual touch tissue imaging (VTI) and virtual touch tissue quantification (VTQ) technology of acoustic radiation force impulse (ARFI) were employed to analyze the relationship between human epidermal growth factor receptor 2 (HER-2) expression and the CEUS and ARFI characteristics of breast cancer

  • A correlation was found between the CEUS and ARFI characteristics of breast cancer and HER-2 expression levels

Read more

Summary

Objective

The purpose of the present study was to explore the correlation between the contrastenhanced ultrasound (CEUS) and acoustic radiation force impulse (ARFI) characteristics of breast cancers and the expression of human epidermal growth factor receptor 2 (HER-2)

Methods
Results
Introduction
Materials and methods
Findings
Discussion