Abstract
In order not to sacrifice nitrided layer thickness and reduce brittle compound layer thickness, Ni-coated pretreatment was carried out with electrodeposition on a pure iron surface, followed by gas nitriding. The brittle compound layer thickness of duplex surface treated samples was reduced, and the nitrided layer thickness increased to 320 μm. The microhardness was 4 times harder, and the wear loss was reduced by 68% compared with the original material. The results indicate that Ni-coated pretreatment could effectively improve microhardness and wear resistance and realize the controlled microstructure of a brittle compound layer of pure iron without compromising nitrided layer thickness. Ni coating plays an important role in ammonia adsorption and decomposition, and in the transfer of active nitrogen atoms during nitriding.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.