Abstract

The response to off-vertical-axis rotation (OVAR) was measured in cats under circumstances in which the signals from the horizontal semicircular canals and otoliths were opposed. Opposition was achieved by sudden acceleration or deceleration during constant velocity OVAR. The degree of opposition was expressed as a canal/otolith ratio where a ratio of unity indicated agreement. For a canal/otolith ratio of 1, the OVAR gain (eye velocity/stimulus velocity) was 0.73 (+/- 0.13). The steady-state OVAR response was, however, reduced if the canals and otoliths were opposed. The reduction depended on the degree of opposition with a fall-off of 0.15 gain/(unit of canal/otolith ratio). These findings are discussed with respect to the central velocity store and the mechanism underlying the generation of the OVAR response.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.