Abstract

BackgroundThe performance of DPIs depends on several physiological (patient-dependent) and technological (device-dependent) factors. The inspiratory airflow rate is the only active force generated and operating in the system for inducing the required pressure drop and eliciting the resistance-induced turbulence needed to disaggregate the powder through the device. The present study aimed to investigate in the most prevalent respiratory disorders whether and at what extent the inspiratory airflow rate achievable when inhaling through a DPIs’ simulator reproducing different intrinsic resistance regimens (low, mid, and high resistance) is affected by peculiar changes in lung function and/or can be predicted by any specific lung function parameter.MethodsThe inspiratory airflow rate was assessed in randomized order by the In-Check DIAL G16 at low, mid, and high resistance regimens in a sample of consecutive subjects at recruitment. Independent predictors of the probability to achieve the expected inhalation airflow rate were investigated by means of a multivariate logistic regression model, specific to the disease.ResultsA total of 114 subjects were recruited (asthmatics n=30; COPD n=50, restrictive patients n=16, and normal subjects n=18). The mean values of the expected inspiratory airflow rate achieved proved significantly different within the groups (p<0.0001), independently of sex and age. In asthmatics and in COPD patients, the mid-resistance regimen proved highly associated with the highest mean values of airflow rates obtained. Low- and high-resistance regimens were significantly less likely to consent to achieve the expected level of inspiratory airflow rate (OR<1 in all comparisons). Restrictive patients performed the lowest airflow rates at the low-resistance regimen (p<0.01). Unlike FEV1, RV in asthmatics (OR=1.008); RV and IRaw in COPD (OR=0.587 and OR=0.901, respectively), and FIF and TLC in restrictive patients (OR=1.041, and OR=0.962, respectively) proved the only sensitive predictors of the inspiratory airflow rate achievable at the different resistive regimens.ConclusionsThe intrinsic resistive regimen of DPIs can play a critical role. The patients’ lung function profile also affects the extent of their inhalation airflow rate. Some specific lung function parameters (such as: FIF; RV; IRaw; TLC, but not FEV1) may be regarded as specific predictors in real-life. In order to optimize the DPI choice, further to the device’s technology, also the current patients’ lung function should be properly investigated and carefully assessed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.