Abstract
The frequency dependence of the complex magnetic susceptibility, χ(ω) = χ′(ω) − i χ″(ω), of a water-based magnetic fluid with magnetite particles, over the frequency range 500 kHz to 2 MHz and at three different temperatures of 30 °C, 40 °C and 50 °C are presented. Based on these experimental measurements, the dependence on frequency, f = (ω/2π) Hz, of the heating rate, ΔT/Δt, of the ferrofluid has been evaluated at these stated temperatures and alternating magnetic field of different amplitudes, Ho = 200 A/m, 400 A/m, 600 A/m, 800 A/m and 1 kA/m.The results show that the preheating of the ferrofluid sample at the desired operating temperature has the advantage of using lower levels of H0 during over a shorter time period, as opposed to the case of an unheated sample. This concept of preheating a sample, has major significance for the treatment of cancer by magnetic hyperthermia in that the patient is subjected to lower values of H0, over the time period of the treatment.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.