Abstract

This paper enhanced the integration-type E&S model and the dynamic E&S model for integrating the impact of DC-biased field and eddy current on vector magnetic properties of electrical steel sheet. B and H of electrical steel sheet are measured under DC-biased and rotating fields. Based on the measured results, the databases of reluctivity and hysteresis coefficients of both the enhanced integration-type E&S model and the improved dynamic E&S model are established for predicting H waveform under any given operating condition. By comparing the H waveform calculated by the enhanced integration-type E&S model and the improved dynamic E&S model with the experimental H waveform, it is found that both two models have good reliability and the improved dynamic E&S model has slightly better accuracy than the enhanced integration-type E&S model.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.