Abstract

The design, construction and operation of a tomographic imaging system on the Compact Toroid Injection Experiment is described. The system measures the total radiated power over energies from visible light up into the extreme ultraviolet. It then reconstructs two dimensional profiles from the data. The reconstruction routine is based on a method known as second order regularization which finds a compromise between smoothness and fit to the data. This method was found to have the best overall fidelity to test images. The hardware and overall reconstruction were calibrated using two different sources. First results from the system under real experimental conditions are presented.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.