Abstract

This paper present a set of procedures based on laser scanning, photogrammetry (Structure from Motion) and operational modal analysis in order to obtain accurate numeric models which allows identifying architectural complications that arise in historical buildings. In addition, the method includes tools that facilitate building-damage monitoring tasks. All of these aimed to obtain robust basis for numerical analysis of the actual behavior and monitoring task.This case study seeks to validate said methodologies, using as an example the case of Saint Torcato Church, located in Guimãres, Portugal.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.