Abstract

Dual-energy computed tomography (DECT) is an imaging technique that detects monosodium urate (MSU) deposits. This study aimed to assess the clinical utility of DECT in the diagnosis of gout. A total of 120 patients with clinical suspicion of gout who underwent DECT were retrospectively enrolled. The sensitivity and specificity of DECT alone, American College of Rheumatology (ACR)/European Alliance of Associations for Rheumatology (EULAR) classification criteria without DECT, and ACR/EULAR criteria with DECT were assessed. Additionally, an analysis of gout risk factors was performed. When artifacts were excluded, any MSU volume provided the best diagnostic value of DECT (AUC = 0.872, 95% CI 0.806–0.938). DECT alone had a sensitivity of 90.4% and specificity of 74.5%. Although ACR/EULAR criteria without DECT provided better diagnostic accuracy than DECT alone (AUC = 0.926, 95% CI 0.878–0.974), the best value was obtained when combing both (AUC = 0.957, 95% CI 0.924–0.991), with 100% sensitivity and 76.6% specificity. In univariate analysis, risk factors for gout were male sex, presence of tophi, presence of MSU deposits on DECT, increased uric acid in serum (each p < 0.001), and decreased glomerular filtration rate (GFR) (p = 0.029). After logistic regression, only increased serum uric acid (p = 0.034) and decreased GFR (p = 0.018) remained independent risk factors for gout. Our results suggest that DECT significantly increases the sensitivity of the ACR/EULAR criteria in the diagnosis of gout.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call