Abstract
The relationship between membrane fouling and cleaning was investigated in terms of flow conditions, transmembrane pressures, pH, membrane properties, and cleaning agents using a stirred batch cell and aqueous albumin solution. Fouling was less at the pH extremes than at the isoelectric point for both retentive and partially permeable membranes. Membranes with partial permeability showed a greater tendency for fouling and were less responsive to cleaning than retentive membranes. The results in the stirred cell were shown to be similar to those for a crossflow module under similar operating conditions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.