Abstract

This paper describes the feasibility and characterization of a novel fast valve concept, which can replace the diaphragms in shock and Ludweig tube facilities. The proposed fast valve system consists of a rotating door and locking camshaft system. The concept was tested in a bench-top scale shock tube facility, which was operated over a driver gas (air) pressure range of 60 to 500 psig, with a duty cycle of 6 seconds. The measured wave speeds (MS = 1.7 – 2.0) were within 3.1% of that predicted by ideal shock tube theory and a statistical repeatability within 7.9 %. However, the post-shock driven gas pressures were approximately half that expected from ideal shock tube theory, which was attributed to losses associated with the mechanism (66% area increase) and incomplete shock wave formation. Nonetheless, these results show promise that the rotating door opening time may be sufficient for repeatable Ludweig tubes and shock wave generation given higher driver gas pressures and a longer test section.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.