Abstract

Based on aqueous medium with low viscosity, poor lubrication, high vapor pressure and corrosion, and other special physical, chemical properties, this paper analyzed the pure water flow through the valve port, the cavitation corrosion, spiral vortex, energy loss, temperature rise and other issues may occur near the entrance. Flow field model has been established by the SolidWorks software. And the internal flow field in visual simulation analysis has been done through the FLUENT software. The pressure, speed, temperature, turbulent kinetic energy cloud pictures have been obtained, the analytical results has been validated. Meanwhile it prepared for structure optimization of pilot valve.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.