Abstract

The concentrations of cocaine and benzoylecgonine (BE) in Standard Reference Material (SRM) 1508, cocaine and metabolites in freeze-dried human urine, were determined at the National Institute of Standards and Technology (NIST, formerly NBS) by two independent methods. For cocaine, one method was based on gas chromatography/mass spectrometry (GC/MS); the other was based on high-performance liquid chromatography (HPLC). For BE, one method was based on GC/MS; the other was based on flow injection analysis/thermospray mass spectrometry (FIA/MS). The results for each pair of methods were statistically evaluated. Concentrations were determined in the SRM for three levels of cocaine and three levels of benzoylecgonine. Methylecgonine, although present in the material, was not determined. For cocaine, the concentrations were 90, 263, and 429 ng/mL of human urine. For BE, the concentrations were 103, 259, and 510 ng/mL of human urine.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.