Abstract

The CDF Plug Upgrade calorimeter, which fully exploits the tile–fiber technique, was tested at the Fermilab meson beamline. The calorimeter was exposed to positron, positively charged pion and positive muon beams with energies in the range of 5– 230 GeV . The energy resolution of the electromagnetic calorimeter to the positron beam is consistent with the design value of 16%/ E ⊕1% , where E is the energy in units of GeV and ⊕ represents sum in quadrature. The non-linearity for positrons is studied in an energy range of 11– 181 GeV . It is important to incorporate the response of the preshower detector, the first layer of the electromagnetic calorimeter which is readout separately, into that of the calorimeter to reduce the non-linearity to 1% or less. The energy scale is about 1.46 pC/ GeV with HAMAMATSU R4125 operated typically at a gain of 2.5×10 4. The response non-uniformity over the surface of a tower of the electromagnetic calorimeter is found to be about 2% with 57 GeV positrons. Studies of several detailed detector characteristics are also presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.