Abstract

To investigate the quantitative relationship between the volume capture of rainfall and carbon emissions from bioretention facilities, this study introduces the concept of the carbon intensity of volume capture of rainfall. The influence of four key factors—climatic conditions, aquifer height, permeability coefficient, and facility area—was investigated using a residential neighborhood in Tianshui, China, as an example. The results reveal that the carbon intensity value is influenced not only by external environmental changes but also by the inherent attributes of bioretention facilities, such as aquifer height, permeability coefficient, and facility area. The maximum carbon intensity value for the volume capture of rainfall was −0.0005 kg CO2/m3, while the minimum was −0.0852 kg CO2/m3, representing a substantial difference of approximately 169 times. Orthogonal experiments identified the facility area as the most significant influencing factor on carbon intensity, with a correlation coefficient of 0.0520. The area of bioretention facilities can be prioritized to meet deployment requirements, taking into account volume capture reduction effects and carbon emissions. For facilities with a high carbon intensity, an emphasis should be placed on enhancing carbon reduction benefits, and various initiatives can be implemented to achieve this goal.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call