Abstract

A number of reports share the conclusion that the captopril test is an adequate screening procedure for the detection of renovascular disease among hypertensive patients. Therefore, we prospectively studied the value of this test in 149 consecutive hypertensive patients. The test was considered positive if plasma renin activity, after an oral dose of 25 mg of captopril, rose by more then 4.44 ng.L-1.s-1 (16.0 ng/mL per hour). The sensitivity of the test was 39%, the specificity was 96%, the positive predictive value was 81%, and the negative predictive value was 79%. No clinically important cutoff point identifying patients with renal artery stenosis could be detected in the values of baseline and stimulated plasma renin activity nor in baseline blood pressure or changes after captopril testing. The low sensitivity makes the captopril test unfit to be used as a screening procedure in an unselected hypertensive population.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.