Abstract

A readout ASIC called CaloRIC, has been developed to fulfil the signal processing requirements for the Silicon-Tungsten (Si-W) electromagnetic calorimeter of the International Linear Collider (ILC). This ASIC performs the complete processing of the signal delivered by the Si-PIN diode of the detector: charge sensitive amplification, shaping, analog memorization and digitization. Measurements show a global integral non-linearity better than 0.2% for low energy particles, and limited to 2% for high energy particles. The measured Equivalent Noise Charge (ENC) is evaluated at 0.6 fC, which corresponds to 1/6 times the signal released by a Minimum Ionizing Particle (MIP). With the timing sequence of the ILC, the power consumption of the complete channel is evaluated at 43 μW using a power pulsing.A new ASIC (CaloRIC_4ch) with four improved readout channels has been designed and is ready for manufacturing.