Abstract

Reasons are given for the selection of initial inductances as a means for calibrating current transformers, the most important of which is the wide use to which they may be put besides the calibration of current transformers. The design and manufacture of the apparatus is described, reasons being given for the choice of the form of the secondary coils of the mutual inductances which is a uniformly wound ring, and of the material used for the core, namely marble. The formula used in calculating the values of mutual inductance is given and its limitations stated. Variations in physical dimensions are given and errors in calculated values discussed. The method of calibrating the mutual inductances is described which illustrates also one method of using the apparatus for measuring mutual inductance. The method of measuring rates and phase-displacements by means of the apparatus, and the merits of various instrument-for obtaining a balance are described and discussed. An artificial method of loading the transformers under test is proposed. Its advantages are pointed out. The use of the apparatus for measuring mutual inductance, self inductance and alternating current resistance is described. In conclusion it is stated that the apparatus has been satisfactory, and has given little difficulty in manufacture.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.