Abstract

AbstractThe uncertainty in a transducer/tensiometer system was assessed with temperature and pressure calibrations. A reference transducer/tensiometer pair was used to factor out temperature related deviations from two monitoring pairs. The reference pair removed most of the deviations, resulting in a high estimate of precision. In contrast to earlier reports of high accuracy, these estimates of accuracy were considerably reduced by a time correlated residual pattern. The calibrations suggested that the electronic components may be responsible for these residual errors and illustrated the need for experimentation which isolates the error among groups of components. The complexity of transducer/tensiometer networks, and the differing response of each component to thermal loading, demonstrated the necessity of using a reference system, which when properly designed can yield reliable pressure readings for soil water.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.