Abstract

14.7 MeV neutrons, the 252Cf neutron spectrum and a cyclotron generated neutron spectrum are considered to irradiate water, tissue-equivalent plastic and standard man tissue and results are given for all these cases. From a knowledge of the target composition, and the cross-sections and kinetics of all the possible neutron induced reactions in the elements hydrogen, carbon, nitrogen and oxygen, the secondary particle spectrum is calculated. By combining with stopping power data for the ions in the target, the charged particle fluence spectra and dose distribution in linear energy transfer are derived. Secondary quantities computed are kerma, energy expanded as nuclear elastic scattering, specific ionization and mean quality factor. Stopping powers have been derived from published atomic stopping powers.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.