Abstract

In this study, the anaerobic baffled reactor contained sediment microbial fuel cell (MFC) was combined with anaerobic/aerobic membrane bioreactor (AnMBR/MBR). The brewery wastewater treatment and membrane fouling mitigation strategies were studied comprehensively. During anaerobic treatment process in this study, the chemical oxygen demand (COD) removal ratio of brewery wastewater could be maintained at 73.87% when the hydraulic retention time (HRT) was reduced from 42.44h to 22.60h. For membrane fouling mitigation in AnMBR, regular aeration was more effective than back flush, and the fouling could be inhibited further when both controlling ways were adopted at the same time. For membrane fouling mitigation in AnMBR of this study, only 0.52%–0.99% of electric energy was required for fouling mitigation, but 31.80% of energy was needed in MBR.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.