Abstract
With improvements in the techniques of microvascular surgery, the Blalock-Taussig shunt has been applied to smaller infants. We report our experience in 17 neonates (mean age 9 days, mean weight 3.2 kg) who underwent emergency shunt operations. The early mortality was 17.6% (3 of 17), with only 1 death (7%) from renal failure and sepsis, in the last 14 patients. Three shunts were patent but inadequate and required a secondary procedure, which was successful in all 3. There were 3 patients with late shunt failures at a mean of 15 months postoperatively, while 2 are still doing well at 15 and 18 months. No patients developed congestive cardiac failure. The late mortality was high (5 of 14), but was due to late shunt failure and was preventable in only 1 patient. These results are encouraging, and we continue to perform the Blalock-Taussig shunt in neonates. It is hoped that improvements in technique will reduce the incidence of inadequate shunts.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.