Abstract

Micro-displacements (fringe patterns) in the bones of the craniofacial complex as seen through laser holography during midpalatal sutural expansion with the Hyrax appliance are used to define the centers of rotation of the maxillary halves in both the frontal and occlusal views. Biomechanical analyses of the maxillary expansion force system are concomitant with the holographic findings and strongly suggest that the stainless steel wires joining the teeth to any expansion device be of the largest diameter possible. In addition, in the case of the Hyrax expansion device, it is recommended that the manufacturer increase the diameter of the activating screw as well as those of the 2 adjacent wire guides. And, importantly, the use of acrylic as a structural member to join the teeth to a sutural expansion device should be avoided if tipping of the maxillary halves is to be minimized, as the acrylic lacks sufficient rigidity. (Am J Orthod Dentofacial Orthop 2000;118:257–61).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.