Abstract
Binaural masking level differences (MLDs) were measured for 10 normal-hearing and 10 cochlear-impaired listeners, at 500 and 2 000 Hz. Maskers were either wide-band (approximately 2 000 Hz), or narrow-band (50 Hz). For wide-band maskers the noise pressure spectrum level was 50 dB/Hz, and for the narrow-band maskers the noise levels were 50 and 60 dB/Hz. At 500 Hz the hearing-impaired listeners show abnormally low MLDs in wide-band noise, but not in narrow-band noise. At 2 000 Hz, the hearing-impaired subjects show abnormally low MLDs only in narrow-band noise at the 50 dB/Hz level. The clinical implications of the results are considered.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.