The effect of column number N and the same column height h of each thermal-diffusion column, on the Frazier scheme performance with total sum of column height ( L = Nh) fixed, has been investigated. The equations, which may be employed to predict the optimal number of columns (generally not integers) for the maximum performance are derived. Accordingly, the best number of columns, which are the integers nearest to, and small than the optimal column numbers, are obtained for practical applications. Considerable improvement in performance is obtainable if the scheme is constructed with the best number of thermal-diffusion columns, instead of using a single column with column height L ( N = 1, h = L). This is because that increasing column height in a thermal-diffusion column, though increasing the performance, will decrease the increment in performance, and finally the performance reaches a limiting value.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.