Abstract
A quantitative review of empirical studies investigating the effects of haptic feedback in teleoperation or virtual reality systems is provided. Several meta-analyses were conducted based on results of 58 studies with 1104 subjects from the medical and other teleoperation domains, revealing positive, substantial effects of kinesthetic force feedback on task performance (Hedges’ g = 0.62–0.75) and force regulation (g = 0.64–0.78) and positive, but small effects on task completion time (g = 0.22). Vibrotactile substitution of force feedback results in significantly lower effects on task performance (g = .21). Yet, exaggerated force production can be avoided effectively. Finally, we found evidence that the magnitude of the force feedback effects are moderated by task characteristics like force regulation demands and complexity.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.