Abstract

This paper assesses the behavior of output voltage and frequency of wind-driven self-excited induction generators with variable excitation capacitances connected to the main and auxiliary windings under different operating conditions. The optimum values of the main winding excitation capacitance for fixed terminal voltage operation under different values of shunt capacitance, load, and speed are also evaluated. The obtained results show that the terminal voltage is highly affected by changing the main winding excitation capacitance. In addition, the frequency is greatly affected by changing the auxiliary winding excitation capacitance. However, under different operating conditions, variation in the output frequency under different values of the main winding capacitance, with fixed auxiliary winding capacitance, is acceptable. Extensive simulations were conducted and the results are discussed in this publication.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.