Abstract

The scope of this study is to look at the effect of supplying a non-prismatic cross-section on the flexural strength of one-way continuous slabs reinforced concrete (RC) with two spans under repeated load. The research aims to study the ability of non-prismatic slabs to increase flexural stiffness which leads to saving construction costs. For this purpose, experimental investigations were carried out; the work consisted of fabrication and testing six two-span RC slabs with the same volume of concrete. Two of them were prismatic with a constant depth, while all the others were non-prismatic with tapered cross-sections having varying depth. Prismatic slabs were stiffer than non-prismatic slabs in all support settings, according to the findings. It is found that providing a tapered slab with a positive or a negative haunch has an insignificant effect on the bearing capacity for a prismatic slab. On the other hand, the tapered slab led to increase the deflection at service load compared to the prismatic slab.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call