Abstract
The 10MW High Temperature Gas Cooled Test Reactor (HTR-10) has been built in Institute of Nuclear and New Energy Technology (INET) and has been operating successfully since the beginning of 2003. The core outlet temperature of HTR-10 is 700°C. To verify the technology of gas-turbine direct cycle, at first INET had a plan to increase its core outlet temperature to 750°C and use a helium gas turbine instead of the steam generator (then the reactor is called HTR-10GT). Though HTR-10 has good intrinsic safety, the design basic accidents and beyond design basis accidents of HTR-10GT must be analyzed according to China’s nuclear regulations due to changed operation parameters. THERMIX code system is used to study the ATWS accident of one control rod withdrawal out of the core by a mistake. After a control rod in the side reflector was withdrawn out at a speed of 1 cm/s by a mistake, a positive reactivity was inserted and the reactor power increased and the temperature of the core increased. When the neutron flux of power measuring range exceeded 123% and the core outlet temperature was greater than 800°C, the reactor should scram. It was supposed that all the control rods in the reflectors had been blocked and the reactor could not scram. Thus the accident went on and the core temperature and the system pressure increased but the reactor shutdown at last because of its natural negative temperature reactivity feedback mechanism. The residual heat would be removed out of the core by the cavity cooling system. During the accident sequence the maximum fuel temperature was 1242.4°C. It was a little higher than 1230°C–the fuel temperature limitation of HTR-10. Now the sphere fuel used in HTR-10GT will also be used in HTR-PM and the temperature limitation raised to 1620°C, so the HTR-10GT is safe during the ATWS of one control rod withdrawal out of the core. The paper also compares the analysis result of HTR10-GT to those of HTR-10. The results shows that the HTR-10GT is still safe during the accident though its operating temperature is higher than HTR-10. The analysis will be helpful to HTR-PM because they have the same outlet temperature of the core.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.