Abstract
The ATLAS Level-1 Central Trigger Processor (CTP) com- bines information from the Level-1 calorimeter and muon trig- ger processors, as well as from other sources such as calibration triggers, and makes the final Level-1 Accept deci- sion. The CTP synchronises the trigger inputs from different sources to the internal clock and aligns them with respect to the same bunch crossing. The algorithm used by the CTP to com- bine the different inputs allows events to be selected on the basis of trigger menus. The CTP provides trigger summary information to the data acquisition and to the Level-2 trigger system, and allows one to monitor various counters of bunch- by-bunch as well as accumulated information on the trigger inputs. The design of the CTP with its six different module types and two dedicated back-planes will be presented.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.