Abstract

In our hypothesis, the newly developed program SPM (surgical procedure manager) will ensure successful standardization and efficiency of the FESS (functional endoscopic sinus surgery) and therefore make a decisive contribution in terms of economization and improvement of intraoperative quality. Between 27th March 2015 and 8th October 2015, data from 259 FESS procedures were collected using the SPM. The study took place at the surgical desk, an operating room in the ACQUA clinic in Leipzig, Germany. 233 FESS (90%) of the total FESS (n=259, 100%) were conducted entirely with SPM. 26 SPM terminations (10%) of 259 FESS remain, which are classified as actual SPM terminations-when the surgeon intentionally stops the SPM. The maximum time slot decreased clearly from 1h39min (period A) to 1h10min (period B). A time reduction can also be seen with the minimum duration of 13.5min compared to 11min. The variability of the time slot also decreases since the standard deviation is reduced by 4.5min. On the basis of available recordings it can be postulated that the application of SPM is suitable for standardization for FESS. Standardization by means of SPM and minimal development can be recognized over a period of time. The SPM makes it possible to transfer the general advantages of mechanization on a concrete FESS and do not influence the medical processes nor even restrict the medical freedom. The users are still entirely free in the implementation of the respective procedure.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call