Abstract

Evaluation and application of tiny, 0.031-in. gage length, constantan foil-strip strain gages for measuring residual surface stresses in beryllium parts are discussed. The strain gages were applied to one side of the beryllium parts at locations known to have high residual surface stresses. Small coupons were machined from the parts and the opposite side of the coupon was chemically milled with a 10 to 20-percent hydrochloric-acid solution. The strain-gage installation was protected with micro-crystalline wax. The etching process required approximately 20 hr at 75°F. Because of their high stability, glass-fiber-reinforced epoxyphenolic strain gages were used rather than the more readily available polyimide-backed strain gages. Details of the strain-gage installation are presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.