Abstract
The dynamic replacement method is appled widely to the soft soil treatment, but is seldom used in retificating pile deviation. By the ways of dynamic replacement method gravel block can form underground, the gravel block can be treated as reaction-froce base, the magnitude of squeeze force needed for retificating pile deviation is related to the scale of gravel block. Take a sheet pile retaining wall for instance, the treatment scheme and paramters calculating method for deviation rectification of support pile was put forward. The project case demonstrate that this method is effective when the layout of gravel column is reasonable to a certain degree, it is a good reference to similar projects.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IOP Conference Series: Earth and Environmental Science
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.