Abstract

Present structural and materials laboratory practice uses transducers (linear variable differential transducers- LVDTs or dial gauges) in determining the displacement of beams. As such displacements can only be measured at points where transducers are fixed and in many cases would be limited. Displacements at any other points, if desired, would be obtained by calculations. This study highlighted the use of photogrammetric multiple images matching technique to measure the vertical displacements. Laboratory experiments involving load test on concrete structures were performed. Validation of the results was done by means of comparing the photogrammetric output against those obtained from the LVDTs. Statistics have shown that the differences in displacements between the two methods are not significant.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.