Abstract
Suspensions and dried preparations of vaccinia virus were exposed to γ-rays in cobalt-60 sources. Suspensions completely inactivated by 6–8 × 105 rad. retained measurable immunogenicity. Dried preparations could not be completely in-activated even by doses of 11 × 106 rad., although the inactivation apparently followed first-order kinetics until about one particle in 107 survived, suggesting that the populations of vaccinia virus in the preparations were heterogeneous.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.