Abstract

This research is a descriptive study with quantitative and qualitative approaches. Data were obtained from five Clinical Practice Hospitals with Focused Group Discussion. Data were analyzed with descriptif Method. The result shows that the radiographers tend to use higher Expossion Factor and Wider Collimation Field. because the Vendor and Aplicant has informed that CR operation need higher energy and the appearance of noise when the image being manipulated in CR will be lower if high mAs and kV are used. Another affecting factor is prefer images with high density. Radiographers tend to use wider Collimation Field to prevent image cut-off, resize-able image in CR, and availability of widest Imaging Plate size (35x43). Based on that results, optimal exposure factor and precise collimation field should be used in CR in order to minimize the patient dose.