Abstract
This paper studies the visible light communication in the elevator. In the tiny space (1.6*1.4*2.3m), it has different distribution of illumination performance compared to the room of common size (5*5*3m). This paper analyzes 4 different lamp distribution strategies, each of which has different performance in the illumination distribution and luminous power. This paper shows that the rectangular line structure of the lamp distribution has the advantages in the illumination and communication. Under this lamps distribution, the average illumination intensity is 497.79[lx]; The mean signal-to-noise ratio (SNR) is 52.99[dB] and the optimal FOV is 65°. The results of simulation show it in the tiny space of the elevator, it can satisfy the demand of illumination and communication.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: DEStech Transactions on Computer Science and Engineering
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.