Abstract

An optical emission spectrographic method has been developed for the quantitative determination of molybdenum, ruthenium, rhodium, palladium, and zirconium in normal uranium metal in the range of 2.5%, 2.0%, 0.30%, 0.20%, and 2.5%, respectively. The precision of the spectrographic method for molybdenum is ±1.0%, ruthenium ±18%, rhodium ±17%, palladium ±21%, and zirconium ± 2.2% of the amounts present The comparison of spectrographic and chemical results on 24 “fissium” alloy samples for molybdenum, ruthenium, rhodium, palladium, and zirconium shows a standard relative deviation from the chemical results of ±3.9%, ±4.3%, ±7.2%, ±6.6% and ±7.5%, respectively. These samples were chosen at random from ingots by using routine sampling procedures