Abstract
Abstract—Switching loss has to be reduced in order to improve converter's performance and efficiency. In high switching frequency, the effect of the loss is much greater. The duty ratio, dead time and inductor value are the limiting parameters which bring implications on the switching loss and hence total gate drive loss. Using PSpice circuit simulator, the optimization of these parameters have been carried out and it is found that the duty ratio, dead time and resonant inductor value are 20 %, 15 ns and 9 nH respectively. The details for choosing these values are presented in this paper.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IACSIT international journal of engineering and technology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.