Abstract

Fracture toughness and fracture mechanism of Ti60 alloy with duplex microstructure under different temperature conditions were investigated in the present work. The experimental result shows that the fracture toughness of CT samples increases from the room temperature (40 MPa m1/2) to 400 °C (71.45 MPa m1/2) but declines at 600 °C (62.55 MPa m1/2). It is observed from fracture surface through SEM that the predominant fracture mechanism has changed from quasi-cleavage fracture at room temperature to ductile fracture at higher temperatures. In addition, the tortuosity of crack propagation path has a limited impact on the fracture toughness. Path selections for crack propagation are obtained through SEM observation which can be summarized as: cut through lamellar α, parallel to lamellar α, bypass the equiaxed αp and cut through the equiaxed αp. Moreover, it is found that the intrinsic contribution is the primary reason leading to the change of the fracture toughness of Ti60 alloy under different temperatures. Meanwhile, it is noteworthy that the area of the crack tip plastic zone increases from RT to 400 °C but decreases at 600 °C, which is seen as the main impact of temperature on fracture toughness. To be exact, the CT sample with a larger area of the plastic zone could provide a higher K1C value. Furthermore, a prediction model of K1C based on tensile properties is established, which has a good accuracy with experimental results. The model is useful in predicting the fracture toughness of Ti60 alloy at different test temperatures.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call