The properties of detectors based on epitaxial layers of silicon carbide (SiC) are presented. It is shown that the developed detectors have good spectrometric characteristics when detecting a particles with energies of up to 8 MeV. The pulse height defect was measured in SiC detectors under irradiation by accelerated xenon ions with different energies. It is shown that this parameter in the spectroscopic analysis of Xe ions is ∼45% of the true energy of the particles in question.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.