Abstract
The insulation system of a flameproof dry-type transformer under the combined thermal, electrical, mechanical, and environmental stresses undergoes gradual deterioration, which ultimately leads to transformer failure. It is hence important to test the aging characteristics of the Nomex insulation paper (aramid paper) which is the main insulation material of the flameproof dry-type transformer. In the paper, thermal and electrical aging of aramid paper specimens was performed, and during which the DP (degree of polymerization) of aramid paper specimens were measured, periodically. The experiment result indicate that DP of aramid paper specimens dramatically declines with the thermal and electrical aging time. And the microstate observation result indicate that the mechanism of the thermal aging and electrical aging for the aramid paper is different.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.